MP-X3-IES 4-15kW 3 Phase All-in-one Residential ESS-3271
Meet the China Moneypro X3‑IES Series: a smarter, sleeker way to power your home with solar. This all‑in‑one system combines a hybrid inverter, intelligent energy management, and expandable batteries into a single streamlined unit. It captures more sunlight, switches to backup power in under 10 milliseconds, and uses AI to save you money by optimizing when you use energy. Whether you’re looking to cut utility bills, stay powered during outages, or future‑proof your home for smart energy programs, this system delivers. With rugged IP66 outdoor protection and long‑life LFP battery support, it’s built to perform reliably for years.
Smart, Integrated Solar + Storage for Modern Homes
The China Moneypro X3‑IES Series is a three‑phase all‑in‑one residential energy storage system that integrates a hybrid solar inverter, intelligent energy management, and expandable battery modules into a streamlined solution. Designed for both on‑grid and backup scenarios, it maximizes solar self‑consumption, supports flexible PV integration, and provides robust backup power with high reliability and safety.
High Yield & Efficient Energy Harvest
Capture More Solar, Use More Power
-
Supports up to 200 % PV oversizing for larger PV arrays relative to inverter power.
-
DC input current up to 20 A per MPPT (higher on larger variants) helps capture high‑power PV modules.
-
Low startup voltage and global MPP scan enhance power harvest throughout the day.
-
High charge/discharge capability (up to ~50 A) ensures responsive energy cycling.
Benefits:
-
More effective daily solar capture for higher self‑consumption.
-
Works well with diverse rooftop orientations and high‑wattage panels.
Reliable Backup & Seamless Power Delivery
Power Continuity When You Need It
-
UPS‑level switchover < 10 ms keeps critical loads running without interruption.
-
EPS output rated at full inverter power with peak overload up to 200 % for 10 s, supporting transient heavy loads.
-
Integrated system can operate in on‑grid, off‑grid, or hybrid modes depending on configuration.
Advantages:
-
Smooth transition between grid and backup power during outages.
-
Flexibility to handle short bursts of high load.
Smart Energy Management
Intelligent, Connected & Adaptive
-
AI‑driven energy management forecasts solar generation and load for optimized usage.
-
VPP‑ready support allows participation in grid flexibility programs (OpenADR, IEEE2030.5).
-
Smart load scheduling and TOU (time‑of‑use) strategies improve cost efficiency.
-
Remote monitoring via cloud provides system insights and performance data.
Benefits:
-
Maximize solar self‑consumption and minimize grid reliance.
-
Intelligent control adapts to tariff and load patterns.
Safe, Durable & Outdoor‑Ready
Built for Everyday Reliability
-
IP66 ingress protection guards against dust and water for sheltered outdoor installation.
-
Multi‑layer safety with optional AFCI and Type II SPD increases system protection.
-
LFP (lithium iron phosphate) battery compatibility offers stable and long life operation.
Advantages:
-
Strong design ensures durability across environments.
-
Multiple safety layers protect both system and home.
Why Choose China Moneypro X3‑IES?
-
Integrated All‑in‑One: Combines hybrid inverter, BMS, and energy storage modules for simplicity.
-
Efficient Solar Use: Up to 200 % PV oversizing and high DC input capture more solar energy.
-
Reliable Backup: Fast switchover and EPS overload support enhance power continuity.
-
Smart Energy Control: AI‑driven system and VPP readiness provide advanced energy management.
-
Durable & Safe: IP66 protection with advanced safety options ensures long‑term reliability.
Key Specifications (Representative Models)
| Model | Max. PV Array Power | MPPT Count | Rated Output Power | EPS Output | Switchover Time | Protection |
|---|---|---|---|---|---|---|
| X3‑IES‑4K | 8 kWp | 2 | 4 kVA | 4 kVA | < 10 ms | IP66 |
| X3‑IES‑5K | 10 kWp | 2 | 5 kVA | 5 kVA | < 10 ms | IP66 |
| X3‑IES‑6K | 12 kWp | 2 | 6 kVA | 6 kVA | < 10 ms | IP66 |
| X3‑IES‑8K | 16 kWp | 2 | 8 kVA | 8 kVA | < 10 ms | IP66 |
| X3‑IES‑10K | 20 kWp | 2 | 10 kVA | 10 kVA | < 10 ms | IP66 |
| X3‑IES‑12K | 24 kWp | 2 | 12 kVA | 12 kVA | < 10 ms | IP66 |
| X3‑IES‑15K | 30 kWp | 2 | 15 kVA | 15 kVA | < 10 ms | IP66 |
Numbers above are typical values; exact specs vary by regional configuration.
Typical Applications
-
Residential Rooftops: Integrated solar + storage for daily energy use.
-
Backup Power Support: Keep essential circuits powered during grid outages.
-
Tariff Optimization: Minimize energy bills with smart TOU strategies.
-
Smart Homes: Connect with EV chargers and smart loads for enhanced control.
FAQ – Common Questions
Q1: What power ratings are available in the X3‑IES series?
It covers 4 kW to 15 kW output variants for diverse household and small commercial needs.
Q2: How quickly does it switch to backup power?
The system offers UPS‑level switchover in < 10 ms.
Q3: Can it handle large PV arrays?
Yes — supports up to 200 % PV oversizing to maximize solar capture.
Q4: Is it suitable for outdoor installation?
With IP66 protection, it can be installed in sheltered outdoor environments.
Q5: What safety protections are included?
Safety features include optional AFCI and AC/DC Type II SPD protection.
Specifications
|
Technical Data
|
MP-X3-IES-4K
|
MP-X3-IES-5K
|
MP-X3-IES-6K
|
MP-X3-IES-8K
|
MP-X3-IES-10K
|
MP-X3-IES-12K
|
MP-X3-IES-15K
|
|---|---|---|---|---|---|---|---|
|
System Overview
|
|||||||
|
Rated output power
|
4 kW
|
5 kW
|
6 kW
|
8 kW
|
10 kW
|
12 kW
|
15 kW
|
|
Number of batteries
|
2
|
3
|
4
|
5
|
6
|
5
|
6
|
|
Nominal capacity
|
10.2 kWh
|
15.3 kWh
|
20.4 kWh
|
25.6 kWh
|
30.7 kWh
|
25.6 kWh
|
30.7 kWh
|
|
Usable energy
|
9.2 kWh
|
13.8 kWh
|
18.4 kWh
|
23.0 kWh
|
27.6 kWh
|
23.0 kWh
|
27.6 kWh
|
|
Max. charge / discharge power
|
10.2 kW
|
15.0 kW
|
15.0 kW
|
15.0 kW
|
15.0 kW
|
15.0 kW
|
15.0 kW
|
|
Degree of protection
|
IP66
|
IP66
|
IP66
|
IP66
|
IP66
|
IP66
|
IP66
|
|
Operating temperature range
|
-30 ~ 53°C
|
-30 ~ 53°C
|
-30 ~ 53°C
|
-30 ~ 53°C
|
-30 ~ 53°C
|
-30 ~ 53°C
|
-30 ~ 53°C
|
|
Allowable relative humidity range
|
4 ~ 100% (condensing)
|
4 ~ 100% (condensing)
|
4 ~ 100% (condensing)
|
4 ~ 100% (condensing)
|
4 ~ 100% (condensing)
|
4 ~ 100% (condensing)
|
4 ~ 100% (condensing)
|
|
Max. operating altitude
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
|
Net weight
|
147.2 kg
|
194.2 kg
|
241.2 kg
|
147.2 / 146.2 kg
|
194.2 / 146.2 kg
|
147.2 / 146.2 kg
|
194.2 / 146.2 kg
|
|
Dimension (W × H × D)
|
730 × 1281 × 209.5 mm
|
730 × 1599 × 209.5 mm
|
730 × 1917 × 209.5 mm
|
730 × 1281 × 209.5 mm / 730 × 1120.5 × 150 mm
|
730 × 1599 × 209.5 mm / 730 × 1120.5 × 150 mm
|
730 × 1281 × 209.5 mm / 730 × 1120.5 × 150 mm
|
730 × 1599 × 209.5 mm / 730 × 1120.5 × 150 mm
|
|
Display
|
LCD
|
LCD
|
LCD
|
LCD
|
LCD
|
LCD
|
LCD
|
|
Cooling concept
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
|
Topology
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
|
Communication
|
RS485, Pocket-X, USB, CAN, DO, DI
|
RS485, Pocket-X, USB, CAN, DO, DI
|
RS485, Pocket-X, USB, CAN, DO, DI
|
RS485, Pocket-X, USB, CAN, DO, DI
|
RS485, Pocket-X, USB, CAN, DO, DI
|
RS485, Pocket-X, USB, CAN, DO, DI
|
RS485, Pocket-X, USB, CAN, DO, DI
|
|
PV Input
|
|||||||
|
Max. recommended PV array power
|
8 kWp
|
10 kWp
|
12 kWp
|
16 kWp
|
20 kWp
|
24 kWp
|
30 kWp
|
|
Max. PV input voltage
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
|
Nominal PV input voltage
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
|
Operating voltage range
|
90 ~ 950 V
|
90 ~ 950 V
|
90 ~ 950 V
|
90 ~ 950 V
|
90 ~ 950 V
|
90 ~ 950 V
|
90 ~ 950 V
|
|
MPPT voltage range
|
110 ~ 950 V
|
110 ~ 950 V
|
110 ~ 950 V
|
110 ~ 950 V
|
110 ~ 950 V
|
110 ~ 950 V
|
110 ~ 950 V
|
|
Start-up voltage
|
140 V
|
140 V
|
140 V
|
140 V
|
140 V
|
140 V
|
140 V
|
|
No. of MPP trackers / Strings per MPP tracker
|
2 / (1/1)
|
2 / (1/1)
|
2 / (1/1)
|
3 / (1/1/1)
|
3 / (1/1/1)
|
3 / (1/1/1)
|
3 / (1/1/1)
|
|
Max. input current per MPPT (MPPT1/2/3)
|
20 A / 20 A
|
20 A / 20 A
|
20 A / 20 A
|
20 A / 20 A / 20 A
|
20 A / 20 A / 20 A
|
20 A / 20 A / 20 A
|
20 A / 20 A / 20 A
|
|
Max. input short circuit current per MPPT
|
25 A / 25 A
|
25 A / 25 A
|
25 A / 25 A
|
25 A / 25 A / 25 A
|
25 A / 25 A / 25 A
|
25 A / 25 A / 25 A
|
25 A / 25 A / 25 A
|
|
AC Input & Output (On-Grid)
|
|||||||
|
Rated output power
|
4 kW
|
5 kW
|
6 kW
|
8 kW
|
10 kW
|
12 kW
|
15 kW
|
|
Rated output current
|
5.8 A
|
7.3 A
|
8.7 A
|
11.6 A
|
14.5 A
|
17.4 A
|
21.8 A
|
|
Max. output apparent power
|
4000 VA
|
5500 VA
|
6600 VA
|
8800 VA
|
10000 VA
|
13200 VA
|
16500 VA
|
|
Max. output continuous current
|
6.1 A
|
8.4 A
|
10 A
|
13.4 A
|
15.2 A
|
20.0 A
|
25.0 A
|
|
Nominal AC voltage
|
3/N/PE, 220 / 380 V; 3/N/PE, 230 / 400 V
|
3/N/PE, 220 / 380 V; 3/N/PE, 230 / 400 V
|
3/N/PE, 220 / 380 V; 3/N/PE, 230 / 400 V
|
3/N/PE, 220 / 380 V; 3/N/PE, 230 / 400 V
|
3/N/PE, 220 / 380 V; 3/N/PE, 230 / 400 V
|
3/N/PE, 220 / 380 V; 3/N/PE, 230 / 400 V
|
3/N/PE, 220 / 380 V; 3/N/PE, 230 / 400 V
|
|
Max. input apparent power
|
10 kVA
|
10 kVA
|
12 kVA
|
16 kVA
|
20 kVA
|
20 kVA
|
20 kVA
|
|
Max. AC input current
|
16.1 A
|
16.1 A
|
19.3 A
|
25.8 A
|
32.0 A
|
32.0 A
|
32.0 A
|
|
Nominal AC frequency
|
50 Hz / 60 Hz
|
50 Hz / 60 Hz
|
50 Hz / 60 Hz
|
50 Hz / 60 Hz
|
50 Hz / 60 Hz
|
50 Hz / 60 Hz
|
50 Hz / 60 Hz
|
|
AC frequency range
|
50 ± 5 Hz / 60 ± 5 Hz
|
50 ± 5 Hz / 60 ± 5 Hz
|
50 ± 5 Hz / 60 ± 5 Hz
|
50 ± 5 Hz / 60 ± 5 Hz
|
50 ± 5 Hz / 60 ± 5 Hz
|
50 ± 5 Hz / 60 ± 5 Hz
|
50 ± 5 Hz / 60 ± 5 Hz
|
|
Adjustable power factor range
|
~1 (0.8 lagging to 0.8 leading)
|
~1 (0.8 lagging to 0.8 leading)
|
~1 (0.8 lagging to 0.8 leading)
|
~1 (0.8 lagging to 0.8 leading)
|
~1 (0.8 lagging to 0.8 leading)
|
~1 (0.8 lagging to 0.8 leading)
|
~1 (0.8 lagging to 0.8 leading)
|
|
THDi (rated power)
|
<3%
|
<3%
|
<3%
|
<3%
|
<3%
|
<3%
|
<3%
|
|
Battery
|
|||||||
|
Battery voltage range
|
160 ~ 800 V
|
160 ~ 800 V
|
160 ~ 800 V
|
160 ~ 800 V
|
160 ~ 800 V
|
160 ~ 800 V
|
160 ~ 800 V
|
|
Communication interfaces
|
CAN / RS485
|
CAN / RS485
|
CAN / RS485
|
CAN / RS485
|
CAN / RS485
|
CAN / RS485
|
CAN / RS485
|
|
BMS module
|
TBMS-MCS0800E
|
TBMS-MCS0800E
|
TBMS-MCS0800E
|
TBMS-MCS0800E
|
TBMS-MCS0800E
|
TBMS-MCS0800E
|
TBMS-MCS0800E
|
|
Battery module
|
TP-HS50E
|
TP-HS50E
|
TP-HS50E
|
TP-HS50E
|
TP-HS50E
|
TP-HS50E
|
TP-HS50E
|
|
Composition
|
TBMS-MCS0800E + TP-HS50E × n + Base Dimensions + Series Box (Required for two columns)
|
TBMS-MCS0800E + TP-HS50E × n + Base Dimensions + Series Box (Required for two columns)
|
TBMS-MCS0800E + TP-HS50E × n + Base Dimensions + Series Box (Required for two columns)
|
TBMS-MCS0800E + TP-HS50E × n + Base Dimensions + Series Box (Required for two columns)
|
TBMS-MCS0800E + TP-HS50E × n + Base Dimensions + Series Box (Required for two columns)
|
TBMS-MCS0800E + TP-HS50E × n + Base Dimensions + Series Box (Required for two columns)
|
TBMS-MCS0800E + TP-HS50E × n + Base Dimensions + Series Box (Required for two columns)
|
|
Battery type
|
LFP
|
LFP
|
LFP
|
LFP
|
LFP
|
LFP
|
LFP
|
|
Nominal capacity / Nominal capacity
|
5.1 kWh / 50 Ah
|
5.1 kWh / 50 Ah
|
5.1 kWh / 50 Ah
|
5.1 kWh / 50 Ah
|
5.1 kWh / 50 Ah
|
5.1 kWh / 50 Ah
|
5.1 kWh / 50 Ah
|
|
Usable energy
|
4.6 kWh
|
4.6 kWh
|
4.6 kWh
|
4.6 kWh
|
4.6 kWh
|
4.6 kWh
|
4.6 kWh
|
|
Standard power
|
3 kW
|
3 kW
|
3 kW
|
3 kW
|
3 kW
|
3 kW
|
3 kW
|
|
Max power
|
5.1 kW
|
5.1 kW
|
5.1 kW
|
5.1 kW
|
5.1 kW
|
5.1 kW
|
5.1 kW
|
|
Max. charge/discharge current
|
50 A
|
50 A
|
50 A
|
50 A
|
50 A
|
50 A
|
50 A
|
|
Cycle life
|
>6000 cycles
|
>6000 cycles
|
>6000 cycles
|
>6000 cycles
|
>6000 cycles
|
>6000 cycles
|
>6000 cycles
|
|
Warranty
|
10 years
|
10 years
|
10 years
|
10 years
|
10 years
|
10 years
|
10 years
|
|
Safety
|
CE, RCM, TUV (IEC62619), ROHS, REACH
|
CE, RCM, TUV (IEC62619), ROHS, REACH
|
CE, RCM, TUV (IEC62619), ROHS, REACH
|
CE, RCM, TUV (IEC62619), ROHS, REACH
|
CE, RCM, TUV (IEC62619), ROHS, REACH
|
CE, RCM, TUV (IEC62619), ROHS, REACH
|
CE, RCM, TUV (IEC62619), ROHS, REACH
|
|
TBMS-MCS0800E dimensions (W × H × D) / Weight
|
730 × 165 × 150 mm / 9.3 kg
|
730 × 165 × 150 mm / 9.3 kg
|
730 × 165 × 150 mm / 9.3 kg
|
730 × 165 × 150 mm / 9.3 kg
|
730 × 165 × 150 mm / 9.3 kg
|
730 × 165 × 150 mm / 9.3 kg
|
730 × 165 × 150 mm / 9.3 kg
|
|
TP-HS50E dimensions (W × H × D) / Weight
|
730 × 318 × 150 mm / 47 kg
|
730 × 318 × 150 mm / 47 kg
|
730 × 318 × 150 mm / 47 kg
|
730 × 318 × 150 mm / 47 kg
|
730 × 318 × 150 mm / 47 kg
|
730 × 318 × 150 mm / 47 kg
|
730 × 318 × 150 mm / 47 kg
|
|
Base dimensions (W × H × D) / Weight
|
730 × 75 × 150 mm / 3.9 kg
|
730 × 75 × 150 mm / 3.9 kg
|
730 × 75 × 150 mm / 3.9 kg
|
730 × 75 × 150 mm / 3.9 kg
|
730 × 75 × 150 mm / 3.9 kg
|
730 × 75 × 150 mm / 3.9 kg
|
730 × 75 × 150 mm / 3.9 kg
|
|
Series box dimensions (W × H × D) / Weight
|
167 × 91.5 × 121 mm / 1.3 kg
|
167 × 91.5 × 121 mm / 1.3 kg
|
167 × 91.5 × 121 mm / 1.3 kg
|
167 × 91.5 × 121 mm / 1.3 kg
|
167 × 91.5 × 121 mm / 1.3 kg
|
167 × 91.5 × 121 mm / 1.3 kg
|
167 × 91.5 × 121 mm / 1.3 kg
|
|
EPS (Off-Grid) Output (With Battery)
|
|||||||
|
Rated EPS output voltage, frequency
|
230 V / 400 V, 50 Hz / 60 Hz
|
230 V / 400 V, 50 Hz / 60 Hz
|
230 V / 400 V, 50 Hz / 60 Hz
|
230 V / 400 V, 50 Hz / 60 Hz
|
230 V / 400 V, 50 Hz / 60 Hz
|
230 V / 400 V, 50 Hz / 60 Hz
|
230 V / 400 V, 50 Hz / 60 Hz
|
|
Rated EPS output power
|
4 kVA
|
5 kVA
|
6 kVA
|
8 kVA
|
10 kVA
|
12 kVA
|
15 kVA
|
|
Peak EPS output power
|
2 times of rated power, 10 s
|
2 times of rated power, 10 s
|
2 times of rated power, 10 s
|
2 times of rated power, 10 s
|
2 times of rated power, 10 s
|
2 times of rated power, 10 s
|
2 times of rated power, 10 s
|
|
Switchover time
|
< 10 ms
|
< 10 ms
|
< 10 ms
|
< 10 ms
|
< 10 ms
|
< 10 ms
|
< 10 ms
|
|
Efficiency
|
|||||||
|
Max. efficiency
|
98.0%
|
98.0%
|
98.0%
|
98.0%
|
98.0%
|
98.0%
|
98.0%
|
|
European efficiency
|
97.7%
|
97.7%
|
97.7%
|
97.7%
|
97.7%
|
97.7%
|
97.7%
|
|
Environment Limit
|
|||||||
|
Ingress protection
|
IP66
|
IP66
|
IP66
|
IP66
|
IP66
|
IP66
|
IP66
|
|
Operating ambient temperature range
|
-35 ~ 60°C
|
-35 ~ 60°C
|
-35 ~ 60°C
|
-35 ~ 60°C
|
-35 ~ 60°C
|
-35 ~ 60°C
|
-35 ~ 60°C
|
|
Max. operating altitude
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
|
Relative humidity
|
4 ~ 100% RH (condensing)
|
4 ~ 100% RH (condensing)
|
4 ~ 100% RH (condensing)
|
4 ~ 100% RH (condensing)
|
4 ~ 100% RH (condensing)
|
4 ~ 100% RH (condensing)
|
4 ~ 100% RH (condensing)
|
|
Overvoltage Category
|
Mains: I, Battery: II, PV: II
|
Mains: I, Battery: II, PV: II
|
Mains: I, Battery: II, PV: II
|
Mains: I, Battery: II, PV: II
|
Mains: I, Battery: II, PV: II
|
Mains: I, Battery: II, PV: II
|
Mains: I, Battery: II, PV: II
|
|
General
|
|||||||
|
Dimensions (W × H × D)
|
717 × 405 × 209.5 mm
|
717 × 405 × 209.5 mm
|
717 × 405 × 209.5 mm
|
717 × 405 × 209.5 mm
|
717 × 405 × 209.5 mm
|
717 × 405 × 209.5 mm
|
717 × 405 × 209.5 mm
|
|
Net weight
|
40 kg
|
40 kg
|
40 kg
|
40 kg
|
40 kg
|
40 kg
|
40 kg
|
|
Cooling concept
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
|
Communication interfaces
|
RS485, Pocket-X, CAN + RS485, DO, DI
|
RS485, Pocket-X, CAN + RS485, DO, DI
|
RS485, Pocket-X, CAN + RS485, DO, DI
|
RS485, Pocket-X, CAN + RS485, DO, DI
|
RS485, Pocket-X, CAN + RS485, DO, DI
|
RS485, Pocket-X, CAN + RS485, DO, DI
|
RS485, Pocket-X, CAN + RS485, DO, DI
|
|
Power consumption (night)
|
< 40 W for hot standby, < 5 W for cold standby
|
< 40 W for hot standby, < 5 W for cold standby
|
< 40 W for hot standby, < 5 W for cold standby
|
< 40 W for hot standby, < 5 W for cold standby
|
< 40 W for hot standby, < 5 W for cold standby
|
< 40 W for hot standby, < 5 W for cold standby
|
< 40 W for hot standby, < 5 W for cold standby
|
|
Topology
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
|
Certificates and approvals
|
IEC62109-1 / IEC62109-2, VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21
|
IEC62109-1 / IEC62109-2, VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21
|
IEC62109-1 / IEC62109-2, VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21
|
IEC62109-1 / IEC62109-2, VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21
|
IEC62109-1 / IEC62109-2, VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21
|
IEC62109-1 / IEC62109-2, VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21
|
IEC62109-1 / IEC62109-2, VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21
|
|
AC auxiliary power supply (APS)
|
Built-in
|
Built-in
|
Built-in
|
Built-in
|
Built-in
|
Built-in
|
Built-in
|
|
Protection
|
|||||||
|
Protections
|
Overvoltage protection, Undervoltage protection, Overfrequency protection, Underfrequency protection, Residual current detection, Over-temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current protection
|
Overvoltage protection, Undervoltage protection, Overfrequency protection, Underfrequency protection, Residual current detection, Over-temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current protection
|
Overvoltage protection, Undervoltage protection, Overfrequency protection, Underfrequency protection, Residual current detection, Over-temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current protection
|
Overvoltage protection, Undervoltage protection, Overfrequency protection, Underfrequency protection, Residual current detection, Over-temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current protection
|
Overvoltage protection, Undervoltage protection, Overfrequency protection, Underfrequency protection, Residual current detection, Over-temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current protection
|
Overvoltage protection, Undervoltage protection, Overfrequency protection, Underfrequency protection, Residual current detection, Over-temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current protection
|
Overvoltage protection, Undervoltage protection, Overfrequency protection, Underfrequency protection, Residual current detection, Over-temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current protection
|
|
Active anti-islanding method
|
Frequency shift
|
Frequency shift
|
Frequency shift
|
Frequency shift
|
Frequency shift
|
Frequency shift
|
Frequency shift
|
|
Surge protection (DC / AC)
|
DC: Type II, AC: Type II
|
DC: Type II, AC: Type II
|
DC: Type II, AC: Type II
|
DC: Type II, AC: Type II
|
DC: Type II, AC: Type II
|
DC: Type II, AC: Type II
|
DC: Type II, AC: Type II
|
|
Arc-fault circuit interrupter (AFCI)
|
Optional
|
Optional
|
Optional
|
Optional
|
Optional
|
Optional
|
Optional
|